800.388.8350

Celebrating 58 Years!

THE INDUSTRY LEADER IN PROVIDING CERTIFIED NON-PROPRIETARY EQUIPMENT.

Elevator Size & Weight

 

Please note that many more options are available.

 

Elevator Capacities

Hoistway Width Dimension

Hoistway Depth Dimension

Clear Inside Car Width Dimension

Clear Inside Car Depth Dimension

Door Opening Width   Dimension

2,000#

7′ 6″

6′ 0″

5′ 8″

4′ 3″

3′  0″

Front Openings Only

 

 

 

 

 

2,000#

7′ 6″

6′ 8″

5′ 8″

4′  3″

3′ 0″

Front & Rear Openings

 

 

 

 

 

2,500#

8′ 6″

6′ 0″

6′ 8″

4′ 3″

3′ 6″

Front Openings Only

 

 

 

 

 

2,500#

8′ 6″

6′ 8″

6′ 8″

4′ 3″

3′ 6″

Front & Rear Openings

 

 

 

 

 

3,000#

8′ 6″

6′ 4″

6′ 8″

5′ 0″

3′ 6″

Front Openings Only

 

 

 

 

 

3,000#

8′ 6″

7′  4 1/2

6′ 8″

5′ 0″

3′ 6″

Front & Rear Openings

 

 

 

 

 

3,500#

8′ 6″

7′ 4″

6′ 8″

5′ 8″

3′ 6″

Front Openings Only

 

 

 

 

 

3,500#

8′ 6″

8′ 1″

6′ 8″

5′ 8″

3′ 6″

Front & Rear Openings

 

 

 

 

 

4,000#

9′ 6″

7′ 2″

7′ 8″

5′ 6″

4′ 0″

Front Openings Only

 

 

 

 

(Center Open)

4,000#

9′ 6″

7′  4 1/2

7′ 8″

5′ 6″

4′ 0″

Front & Rear Openings

 

 

 

 

(Center Open)

4,500#

7′ 6″

10′ 0″

5′ 8″

8′ 0″

4′ 0″

Front Openings Only
“Hospital”

 

 

 

 

(2 – Speed)

4,500#

7′ 6″

11′ 0″

5′ 8″

8′ 0″

4′ 0″

Front & Rear Openings
“Hospital”

 

 

 

 

(2 – Speed)

 

*Width dimensions shown are per 2000/’02 Code (Pennsylvania); reduce by 2” when later Code is in effect. Non-standard hoistway sizes can be accommodated at no change in cost.

 

For typical Traction Type Elevators – Add 12” to the hoistway width or depth based on door configuration. Note: Standard Pit Depth 6’ 0”  Overhead 15’ 0”   

 

The above dimensions are for typical Hydraulic Type Elevators.  Note: Standard Pit Depth 4’ 0”  Overhead 12’ 3”      

 

For typical Roped Holeless Hydraulic Type Elevators – Add 2-4” to hoistway width based on capacity. Confirm with Eastern. Note: Standard Pit Depth 4’ 0”  Overhead 13’ 6”  

 

Machine room must be a minimum of 50 square feet with an out-swing door and at least 6’ 0” in one direction OR 60 square feet with an in-swing door and at least 7’ 0” in one direction.  Please note that keeping the machine room adjacent to the elevator hoistway reduces cost.